8W-01 WIRING DIAGRAM INFORMATIONTABLE OF CONTENTSpage pageWIRING DIAGRAM INFORMATIONDESCRIPTIONDESCRIPTION - HOW TO USE WIRINGDIAGRAMS ...
STANDARD PROCEDURE - TESTING FOR ASHORT TO GROUND ON FUSES POWERINGSEVERAL LOADS(1) Refer to the wiring diagrams and disconnect orisolate all items on
CONNECTORREMOVAL(1) Disconnect battery.(2) Release Connector Lock (Fig. 10).(3) Disconnect the connector being repaired fromits mating half/component.
Fig. 11 EXAMPLES OF CONNECTOR SECONDARY TERMINAL LOCKS1 - Secondary Terminal Lock8W - 01 - 12 8W-01 WIRING DIAGRAM INFORMATION DRCONNECTOR (Continued)
Fig. 12 TERMINAL REMOVAL1 - TYPICAL CONNECTOR2 - PICK FROM SPECIAL TOOL KIT 66803 - APEX CONNECTOR4 - PICK FROM SPECIAL TOOL KIT 66805 - AUGAT CONNECT
DIODEREMOVAL(1) Disconnect the battery.(2) Locate the diode in the harness, and removethe protective covering.(3) Remove the diode from the harness, p
WIRESTANDARD PROCEDURE - WIRE SPLICINGWhen splicing a wire, it is important that the cor-rect gage be used as shown in the wiring diagrams.(1) Remove
Fig. 1 WIRING DIAGRAM EXAMPLE 18W - 01 - 2 8W-01 WIRING DIAGRAM INFORMATION DRWIRING DIAGRAM INFORMATION (Continued)
Fig. 2 WIRING DIAGRAM EXAMPLE 2DR 8W-01 WIRING DIAGRAM INFORMATION 8W - 01 - 3WIRING DIAGRAM INFORMATION (Continued)
Fig. 3 WIRING DIAGRAM SYMBOLS8W - 01 - 4 8W-01 WIRING DIAGRAM INFORMATION DRWIRING DIAGRAM INFORMATION (Continued)
TERMINOLOGYThis is a list of terms and definitions used in thewiring diagrams.LHD...Left Hand Drive VehiclesRHD ...Right Han
DESCRIPTION - CIRCUIT FUNCTIONSAll circuits in the diagrams use an alpha/numericcode to identify the wire and it’s function. To identifywhich circuit
DESCRIPTION - CONNECTOR, GROUND ANDSPLICE INFORMATIONCAUTION: Not all connectors are serviced. Someconnectors are serviced only with a harness. A typ-
• Ohmmeter - Used to check the resistancebetween two points of a circuit. Low or no resistancein a circuit means good continuity.CAUTION: Most of the
STANDARD PROCEDURE - TESTING OFVOLTAGE POTENTIAL(1) Connect the ground lead of a voltmeter to aknown good ground (Fig. 7).(2) Connect the other lead o